file size: 40 MB, Max. Please see the list below for the correct files: 3. this was Friday morning 07:01, Radio silence from then even after more than 14 mails to countless contacts. My info for firmware is the same however the MAIN: shows 3381-1515. I am looking to understand how I check the firmware version to ensure they have the latest and if not how to obtain the latest and upgrade. China. The version numbers exist to keep track of the differences in the compiled software code that runs on embedded devices, i.e., firmware. Dont they have some checksum checking? can be plugged into WiFi RS232 port located on the bottom If the average grid voltage is above that value for 10mins, the inverter will trip off (disconnect from the grid). HMI: Ver 0000-C362 Main: Ver -9022-1725. Protocol Version:V0.2.0.1 Have no idea what (if anything) has changed. Hi can any one help please Deye did an firmware upgrade today i only saw now that my inverter is showing off grid but my grid is on . Product Size. Deye SUN-5K-SG03LP1-EU Its not that I cant its that Im a little scared to blindly update it seen to many people having issues with deye updates so was hoping somebody could confirm their version numbers to give me a little more confidence. MAIN_2:V0.7.1.7 The single-phase inverter is one of the best options for residential applications thanks to its smaller size and local LCD display and buttons. Model: Deye 8 kw single phase. Factory cover over 15,000m² and complete production and testing equipment, Deye has become a . Das hat mich eigens an Zeit gekostet und viel nachdenken . Protocol Version:V0.2.0.1 (for Caribbean use, for example) 6) Feature enhancements/bugs or other notes. communication at the same time. On the SolarAssistant configuration page, select "Deye, SunSynk, Sol-Ark" as your inverter model. Interface now says Off Grid instead of a red x when there is load shedding. Maybe that is why they supplied version 6.0.2.2. some versions use the same hardware and KW are defined by firmware and they don't want us to buy a 5K and upgrade for higher without paying extra. I can also reveal that no problems have been observed with the new version. Filenames URL Structure How can i fix this Thank you. That certainly saved buying new ones. Also, with built-in zero-export function (external CT is needed), it offers true ease and comfort for PV system operators and installers. On the SolarAssistant configuration page, select "Deye, SunSynk, Sol-Ark" as your inverter model. SUN-SG03LP1-EU 5KW updated beginning of September. Display as a link instead, × I don't have release notes and the only other way to figure out what visible changes took place is to look very carefully at two different versions and note the differences. Januar 2023 #1 So, nach einigen Stunden Recherche meine Zusammenfassung aus verschiedenen laaangen Threads: Im Web-Interface unter Upgrade / Upgrade firmware kann man eine Datei hochladen und upgraden. HMI: Ver 0000-C361 1 Jun 20, 2022 #1 I have two Deye 8K Hybrid Inverters installed and being monitored via SolarAssistant. . Updated to what I assume is the latest. You must log in or register to reply here. I would appreciate it if you could share the files. It's. I mean really? It may not display this or other websites correctly. Proceed at your own risk though. Their last mail was "We have replaced the firmware for you. P.S. If I set it to prioritize the batteries, it does not do it. Δdocument.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); No.26 South Yongjiang Road, Beilun, Ningbo, Zhejiang, 315806 P.R. You use the logger's webpage. There are no solar panels in this setup so I can not provide observations on their function before and after the firmware upgrade. Main differences from a menu side seem to be around the grid power settings available. Follow along with the video below to see how to install our site as a web app on your home screen. I noticed at least two changes in the interface between the two versions. HMI: Ver 0000-C35A Main: Ver -9014-1725. I was shared a bin files before, but I have not managed to get the latest. Requested an update as I was having a few generator issues. be connected to this port. Thanks. Setting parameters and FW update remotely, which makes PV plant O&M easier. Your previous content has been restored. The single-phase inverter is one of the best options for residential applications thanks to its smaller size and local LCD display and buttons. When I asked them for an upgrade I mentioned that I was having trouble getting the inverter to talk to the batteries in Lithium mode so I have it setup to use voltages. supports the Deye inverter, it will most likely not work. I'm sure that could help someone. Also developers seem to not enjoy writing release notes. Februar 2023 Update vom 03.04.2023 Nutzer melden sporadische Netzwerkausfälle beim Deye Wechselrichter Mehrere Kunden haben in den letzten Tagen gemeldet, dass der Deye Wechelrichter morgens nicht mehr "angelaufen" ist. Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs.Setting parameters and FW update remotely, which makes PV plant O&M easier. I did get them to also update the wireless dongle remotely. See, Note with the latest 16kW models/firmware the BMS port is used for SolarAssistant monitoring and battery CAN file size: 40 MB, Max. Setting parameters and FW update remotely, which makes PV plant O&M easier. You can post now and register later. Requested an update as I was having a few generator issues. Your link has been automatically embedded. Die Sicherheitslücke in dem . Grid Interactive and Inspection Approved 48V System, Solar Friendly Heat Pump Air Conditioners. Inverter stays in standby mode and does not charge batteries. Main differences from a menu side seem to be around the grid power settings available. I have "bricked" exactly one personal device when I forced the firmware for a different piece of hardware on it. I'll post it here if they eventually send it. Der SUN 600/800/1000G3 ist optimiert, um die heutigen Hochleistungs-PV-Module mit bis zu 500 W Leistung und dualem MPPT effektiv aufzunehmen. They explained to me before that the mcu bin is for the lcd, and the other one is for the main board. https://workupload.com/file/M4WMQxJSjQd. The SUN 600/800/1000G3 is optimized to accommodate today's high output PV modules effectively with up to 500W output and dual MPPT. To "unbrick" it I had to solder some pins onto the PCB to be able to connect a serial cable and resurrect it by installing the correct firmware on it. Only post the firmware details here. version, the other main firmware version numbers match exactly with what the Sunynk thread has as the latest. Use Energy Pal to have professionals install an offgrid system. Only post the firmware details here. Although I see in a separate thread that my troubles may be related to faulty cables. Clear editor. Anmelden Datenschutz-Bestimmungen Datenschutz-Bestimmungen Does anyone here have the firmware files even it is outdated. How in the hell would the firmware update push through if the file is not for the specific hardware? If you buy any random USB RS485 RJ45 cable on Amazon, Ebay, Takealot, etc. You can check the sticky thread in this forum. What is the procedure to upgrade the firmware and what do you need? If you have an account, sign in now to post with your account. Follow along with the video below to see how to install our site as a web app on your home screen. I kinda want to hoard these files for future reference. Description Higher yields / Safe / Smart / User-friendly The SUN 600/800/1000G3 is a new generation grid-tied microinverter with intelligent networking and monitoring systems to ensure maximum efficiency. The startup voltage of 250V, much lower than 600V of other products, which makes the inverter start up earlier to generate more power with longer working time. Update file and manual, to update from 3382 to 3384 only for the specified inverter model. I asked the Deye support team to update my 8Kw inverter, they said that they could not and sent two files to me. Not up for DIY? Smart Monitoring Platform. That was when the 9.9a clipping issue for 5kW. Some people are "aint broke aint fix". You nailed everything what I wanted to say sir! Followers 1 Reply to this topic Start new topic 1 2 3 Next Page 1 of 3 recre8 Members 82 Posted February 28, 2021 Hi Guys I'm struggling with an issue with my Deye-branded 5kW inverter that seems to limit the PV current to exactly 9.9A, which severely degrades the maximum power I can get from my PV string. I have upgraded to the latest firmware that Deye support sent me for my Deye 8KW inverter. I once had this funny experience from a distributor that I requested an update and told me "dont, its just a change in version numbers" . I also noticed that other than the HMI (Human Machine Interface??) MAIN_2:V0.7.1.7 efficiency up to 98.7%, 176Vac~242Vac(this may vary with grid standards), CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11, IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2. MAIN: Ver 0-3384-151 Lastest firmware deye 8KUS is 5221 for the mcu2, Możesz zmienić oprogramowanie przez WiFi logger, wprowadź jego IP w przeglądarce, po zalogowaniu zobaczysz tam opcje, oprogramowanie wyśle Ci usługę deye sun pocztą e-mail. not yet. Interface now says Off Grid instead of a red x when there is load shedding. SUN 5/6/8/10/12K-SG is brand new three phase hybrid inverter with low battery voltage of 48V, ensuring the system safe and reliable. Copyright © 2023 Ningbo Deye Technology Co., Ltd. | Designed by, Higher yields / Safe & Reliable / Smart / User-friendly. I am installing my first Deye inverter and from experience with SunSynk I need to update the invertor if used with Revov batteries. Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs. Higher yields / Safe & Reliable / Smart / User-friendly If your inverter is on SOLARMAN and you email support with your serial number and ask to be upgraded, they’ll upgrade you at some point, but your inverter will reboot and you’ll loose power for a few minutes if you’re using it as an UPS power source. Some updates require an additional LCD update, so if you run a version older than 3382, i do not suggest you to update. Don't tell anyone but if the underlying firmware is the same then it may be possible to flash a Deye with Sunsynk firmware and vice versa. Check your battery settings in the inverter, if the voltages are wrong then that could explain why your inverter has been complaining about DC Low Voltage for more than a year. The labelling of the RS485 monitoring port is sometimes not intuitive. The inverter does not behave like it should. These inverters have two ports that can be used for monitoring. Ah, fair enough. Module Version No:LSW3_15_FFFF_1.0.86D Paste as plain text instead, × This is a normal USB serial cable available from most electronic stores. JavaScript is disabled. Deye service department stopped responding after they flashed my inverter with the wrong firmware. Nun hat Deye jedoch angekündigt, das Firmware-Update automatisch auf allen Wechselrichtern einzuspielen, die mindestens 30 Minuten mit dem Internet verbunden sind. If you have an account, sign in now to post with your account. Please see the list below for supported models. Can someone help me with an issue with my Deye 8kw inverter? USB ports. Sadly, the 15kHz noise is still there. Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs. Anstatt alle 600W WR wegzuwerfen und gegen 800W zu tauschen sollten wir hier mal alles zusammentragen was wir tun können um das selber bzw. Accepted file types: jpg, gif, png, pdf, Max. This happened after a firmware update was requested. communication at the same time. Not up for DIY? Hersteller Deye reagierte am 8. They suggested that you update the lcd first to avoid reboot, then finally the board (3382). This was on 23 Feb 2023 and the wireless logger dongle has been working well to date. Could you drop me a DM regarding that 15KHz noise you have man? Lucky you, Deye did not seem inclined to send me any files or guides. The BMS port is used for SolarAssistant Anyone know if the Deye and OHM (also made by Deye and appear identical) inverters share the same firmware? Deye Firmware Tracker Thread themizz May 4, 2022 Prev 1 2 C cods4 Solar Enthusiast Joined Sep 21, 2021 Messages 174 Oct 6, 2022 #21 The middle section are the parameters that the grid needs to fall into after the inverter will reconnect to the grid. Copyright © 2023 Ningbo Deye Technology Co., Ltd. | Designed by, Higher yields / Safe & Reliable / Smart / User-friendly. can be plugged into the RS485 port located on the inside the inverter. 180Vac~300Vac(this may vary with grid standards), CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11, IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2, 2 MPP tracker, Max. I have just been updated to C362 from C35C. This is one possible reason why a manufacturers may not want to make the firmware files available for download. MAIN_1:V6.0.2.2 You are using an out of date browser. Inverter was installed 2 days ago and now it is not working properly. This series inverter is specially designed for 127/220Vac three-phase system, especially suits for South American areas. has anybody done a manual upgrade before and know what deye's naming convention is? efficiency up to 97.5%. The BMS port is used for SolarAssistant monitoring and battery CAN communication at the same time. China. Firmware Update Process Based on a few forum entries and the answer from Deyes support the Inverters should auto-update to the latest version when being up and running for 30 minutes. The middle section are the parameters that the grid needs to fall into after the inverter will reconnect to the grid. Display as a link instead, × How do I go about it? Version Information For a better experience, please enable JavaScript in your browser before proceeding. I got mine 3rd March, same version as yours. It may not display this or other websites correctly. And the overvoltage 10min average is fairly self explanatory. You sure it is 3382-1515. Is it essentially required to update them, and how is the procedures to do that through Solarman? Version Information See. Max 4 MPP tracker, Max. Higher yields / Safe & Reliable / Smart / User-friendly A purpose Step 2 - Configure SolarAssistant to connect to a Deye/SunSynk/Sol-Ark. Contribute to dasrecht/deye-firmware development by creating an account on GitHub. It looks like you have a newer Human Machine Interface (C362) than what I have (HMI:VC.3.5.D) but they seem to have downgraded your main firmware slightly from 6.0.2.2 to 6.0.2.0. Why aren't these files just available from their website? It is one click to start a new thread for anything else. USB ports. i am now not sure which one is for the inverter software and which is the inverter firmware. Emailed Deye support but still waiting for a response. All the problems you have mentioned seem to relate to batteries. However, as someone who has compiled release notes, not everything that gets changed makes it into the release notes. You cannot paste images directly. Can you downgrade firmware? People really should make sure they know what they are talking about before spreading nonsense like that. Note: This feature currently requires accessing the site using the built-in Safari browser. When using this option, you will not be able to use the standard Deye/SunSynk/Sol-Ark dongle as the dongle can only (Not actual screenshot. SolarAssistant connects to these inverters via a physical cable. Liegt als an der Firmware oder Register Einstellungen. Select the USB port where your inverter is connected. Equipped with large LCD and buttons, easy to operate and maintenance. Im glad you started this thread although there is already for sunsynk which in my opinion is identical in main firmware, only HMI will vary, so I could track if there is an update. On 2023/04/09 at 12:11 AM, Oberfail said: On 2023/02/20 at 4:02 PM, SmittySmit said. Any questions about features or troubleshooting should be on a new thread. Hier meine Infos damit der Deye Wechselrichter auch per App oder in der cloud Daten liefert. Your previous content has been restored. We're playing numbers and shooting aimless here without the changelog. durch Deye machen zu lassen. I.e it has tripped for some reason (low frequency for example). multiple inverters, you need to multi-select multiple HMI:VC.3.5.D One would think they would, but no. Posted June 1, 2022 This thread is for tracking the latest Deye Inverter firmware. Max 4 MPP tracker, Max. I'm afraid this will cause them to stop their willingness to update firmwares to people who just want updated firmware without problems. Open station supports one-click installation and registration Problem support one-click dispatch and navigation As it turns out it seems that it was not so much the settings in the firmware but the firmware code that uses those settings. It does not use or integrate with the WiFi dongle 2 MPP tracker, Max. Deye sent new firmware which resolved the problem. Deye full series inverter products support remotely shut down immediately when the accident occurs. If so, does anyone have working firmware to upload for this model? Select the USB port where your inverter is connected. Aren't Deye publishing official firmware releases with official release notes on an official release channel? Power Forum. Latest Firmware 0000-C35C adds new Grid Settings. You are using an out of date browser. Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs.Setting parameters and FW update remotely, which makes PV plant O&M easier. Note: This feature currently requires accessing the site using the built-in Safari browser. Each inverter will require it's own USB cable. SUN-(1-4)K-G04P1-EU-AM1-String Manual-Ver2.-Deye-13A; SUN-(3.6-6)K-G-String Manual-Ver2.-Deye-12.5A; SUN-(7-10.5)K-G-String Manual-Ver2.-Deye-25A The SUN 600/800/1000G3 is optimized to accommodate today's high output PV modules effectively with up to 500W output and dual MPPT. On 2023/02/23 at 11:10 AM, krugerjq said: On 2022/06/01 at 9:06 PM, SmittySmit said. Prior to that I had managed to resurrect multiple pieces of hardware at work that were considered broken by following the recovery process to update the firmware on them. 【Rich Equipment Types】 breaking the traditional limitation, it can comprehensively. Same issue happend to me they flashed my inverter (3k 24v) with wrong inverter(3.6k 48v) and reflashed with the right one, but the inverter still recognise himself as 3.6k 48v, How did you solve your problem please help. Is there a link for the firmware files, or did Deye do the upgrade remotely? Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs. Each inverter will require it's own USB cable. Need Help? If anyone every has a specific "XYZ" problem when running one version of the firmware that is then resolved when Deye support updates their inverter to a newer version containing the fix then they would be able to report that the new version contains fix for "XYZ" version. Der SUN 600/800/1000G3 ist optimiert, um die heutigen Hochleistungs-PV-Module mit bis zu 500 W Leistung und dualem MPPT effektiv aufzunehmen. drew on paper, then reproduced using MS Paint), Solar Equipment Reviews and Technical Support. Solar Equipment Reviews and Technical Support. × Your request for help is less likely to be seen here and you are pulling this thread off-topic for other people who are looking for firmware versions. T themizz Solar Enthusiast Joined Extended System Version:V1.1.00.0F monitoring and battery CAN communication at the same time. Brand: Deye | Category: Inverter | Size: 5.85 MB Table of Contents. Surprisingly after 5982 they went down to 5213, I've also been updated to C35C after I had some issues with parallel communications between inverters on C3FC. Urheberrechte ©Ningbo Deye Inverter Technology Co., Ltd. Alle Rechte vorbehalten. I hope uploading firmware files become a norm in this thread and as detailed as this. 4. Deye SUN-5K-SG03LP1-EU User Manual (46 pages) Hybrid Inverter. If you have multiple inverters, you need to multi-select multiple Please specify: 1) HMI (LCD) and Main (Control Board) Versions 2) Original firmware or upgraded 3) Date of upgrade 4) Inverter Model 5) Split Phase? * to 6.x so I can't tell you in what version the changes were introduced. Also, with built-in zero-export function (external CT is needed), it offers true ease and comfort for PV system operators and installers. I.e it has tripped for some reason (low frequency for example). The SUN 600/800/1000G3 is a new generation grid-tied microinverter with intelligent networking and monitoring systems to ensure maximum efficiency. files: 3. I'm a guy that if there is a firmware update, then it literally means there is an update to atleast improvement if not fix. Setting parameters and FW update remotely, which makes PV plant O&M easier. The one thing where people get scared of firmware updates is that if you mess up the update process, e.g., by interrupting it or using the wrong firmware then you can render the device inoperable or "bricked". Logger / Wireless Dongle: built USB RS485 cable Btw in my earlier reply I did not mean that your batteries were faulty but that the inverter may have had the wrong settings for the battery stored in its firmware and thus did not want to charge them. See the 2 in 1 BMS port. A USB serial cable #1 Moin Zusammen, das Thema wird ja bald interessant. HMI:VC.3.5.D available. Upload or insert images from URL. I've just received update to the above mentioned firmware after requesting from Deye. port. Product Features . You can post now and register later. JavaScript is disabled. Deye smart cloud big data will help you to build your own photovoltaic power station in the shortest time. Need Help? you might already have. That assumes of course that the firmware is distributed in separate files or the separate files are bundled together in a way that can be unpacked. They have to pay expensive salaries to software and hardware engineers to figure out and fix those bugs, develop new features and then verify that they are working as expected without breaking something else. Is a special cable required? Did you manage to do the firmware update? Where do I plug the cable in? If anyone gets hold of the actual firmware files for the same main version for each brand I'll see if I can unpack them and verify if the contents are identical and not just the version numbers.